Description

CMS50D2 Pulse Oximeter is a non-invasive device intended for the spot-check of oxygen saturation of arterial hemoglobin (SpO2) and the pulse rate of adult and pediatric patients in home and hospital environments (including clinical use in internist/surgery, anesthesia, intensive care ect.). This device is not intended for continuous monitoring.

Read Important Info about Defibrillator Cabinets   

Features

  • SpO2 value display
  • Pulse rate value display, bar graph display
  • Pulse waveform display
  • PI value display
  • The display mode can be changed
  • Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
  • Pulse sound indication and over limit indication


  • Display Mode: 0.96" Dual-color OLED display(blue and yellow
  • Pulse sound indication and over limit indication
  • Screen Resolution: 128*64
  • SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
  • Accuracy: 70%~100%:±2% ,Below 70% unspecified.
  • PR Measuring Range: 30 bpm~250 bpm, (the resolution is 1 bpm)
  • Accuracy: ±2 bpm or ±2% (select larger)
  • PI Measuring Range: 0 %~ 20%
  • Accuracy: When the PI measure range is 1%~20%,the permission of absolute error is ±1%, when the PI measure range is 0%~0.9%,the permission of absolute error is ±0.2%
  • Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
  • Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%
  • Power Consumption: Less than 80 mA
  • Voltage: DC 2.6 V - 3.6 V
  • Power Supply: 1.5 V (AAA size) alkaline batteries × 2  
  • Safety Type: Interior Battery BF Type